Fireplace & Chimney Inspections: 3 Levels of Inspections

Home » Furnaces, AC's & Fireplaces » Chimneys » Fireplace & Chimney Inspections: 3 Levels of Inspections

Published: April 27, 2014 Last Updated: February 16, 2015
House fire fireplace

Chimney Inspection

A chimney inspection is different from having your chimney swept. One is an inspection, the other is a cleaning. Often a person or company will do both if desired. However, they need to be properly qualified.

Chimneys that are damaged, leaning or cracked may be inspected to determine if the crack or damage is cosmetic and not too serious in nature, or if repair work should be done. Chimney inspections are generally available on three different levels.

Three Levels of Chimney Inspections

“Chimney Safety Institute of America” describes three levels of inspections.

Level 1 inspections

If your appliance or your venting system has not changed and you plan to use your system as you have in the past, then a Level 1 inspection is a minimum requirement. A Level 1 inspection is recommended for a chimney under continued service, under the same conditions, and with the continued use of the same appliance. In a Level 1 inspection, your chimney service technician should examine the readily accessible** portions of the chimney exterior, interior and accessible* portions of the appliance and the chimney connection. Your technician will be looking for the basic soundness of the chimney structure and flue as well as the basic appliance installation and connections. The technician will also verify the chimney is free of obstruction and combustible deposits.

Level 2 Inspections

A Level 2 inspection is required when any changes are made to the system. Changes can include a change in the fuel type, changes to the shape of, or material in, the flue (i.e. relining), or the replacement or addition of an appliance of a dissimilar type, input rating or efficiency. Additionally, a Level 2 inspection is required upon the sale or transfer of a property or after an operation malfunction or external event that is likely to have caused damage to the chimney. Building fires, chimney fires, seismic events as well as weather events are all indicators that this level of inspection is warranted. A Level 2 inspection is a more in-depth inspection than a Level 1 inspection.

When a Level 1 or Level 2 inspection suggests a hidden hazard and the evaluation cannot be performed without special tools to access concealed areas of the chimney or flue, a Level 3 inspection is recommended.

Level 3 Inspections

A Level 3 inspection addresses the proper construction and the condition of concealed portions of the chimney structure and the flue. Removal or destruction, as necessary, of permanently attached portions of the chimney or building structure will be required for the completion of a Level 3 inspection. A Level 2 inspection includes everything in a Level 1 inspection, plus the accessible portions of the chimney exterior and interior including attics, crawl spaces and basements. It will address proper clearances from combustibles in accessible locations. There are no specialty tools (i.e. demolition equipment) required to open doors, panels or coverings in performing a Level 2 inspection. A Level 2 inspection shall also include a visual inspection by video scanning or other means in order to examine the internal surfaces and joints of all flue liners incorporated within the chimney. No removal or destruction of permanently attached portions of the chimney or building structure or finish shall be required by a Level 2 inspection. Level 3 Inspections– A Level 3 inspection includes all the areas and items checked in a Level 1 and a Level 2 inspection, as well as the removal of certain components of the building or chimney where necessary. Removal of components (i.e., chimney crown, interior chimney wall) shall be required only when necessary to gain access to areas that are the subject of the inspection. When serious hazards are suspected, a Level 3 inspection may well be required to determine the condition of the chimney system.

Additional Resources



Subscribe
Notify of

1 Comment
Oldest
Newest Most Voted
Inline Feedbacks
View all comments

1 inspection says replace back refactoy panel, other says replace complete prefab fireplace..unlisted heat deflector installed w/sharp nails… and cracks in back/floor. Who do I trust?

1
0
Would love your thoughts, please comment.x
()